iDAQ-938 8-slot USB 3.0 iDAQ Base Unit

  • Device model: DF-RP-1061
  • Brand: Advantech
Price to be announced

Viewed 14705 times

Use iDAQ distributed modular high-speed acquisition solution for test and measurement applications, like NVH and battery Testing, Factory production lines, Laboratory research or infrastructure applications. The iDAQ series splits traditional functions in PCI/PCIe cards and USB modules into several smaller functional units. Unlike traditional multi-function cards with fixed I/O and functions, each iDAQ module has only one function, such as digital input, or analog input.

8-slot USB chassis designed for portable sensor measurement systems creation.

Features

  • USB 3.0 SuperSpeed
  • Wide-range power input
  • LED status indicators
  • Physical ID switch for multiple module identification
  • 8 iDAQ slots
  • 2 programmable function pin for timing signal (trigger, clock) input/output

Product Specification

Download IDAQ-938-A Specification in PDF [ENG]

Model iDAQ-938-A
iDAQ Chassis
Slot 8
Digital Input
Channels 2
Digital Output
Channels 2
Power Requirements
Input Voltage 10 – 30 VDC
Environment
Vibration Protection 5 Grms, random
Shock Protection 30 G, half sine

 

Support hot swap

The iDAQ module supports hot swapping and maintenance is very simple. When an iDAQ module is integrated into a machine as a measurement device, it may become damaged due to on-site conditions after a long period of continuous use. Hot-swap replaces damaged modules without interrupting the operation of the module, avoiding the trouble of shutting down and restarting key equipment (such as servers that require continuous operation). In addition, in laboratory scenarios, the measurement signal type can change according to different test procedures according to actual needs, so the hot-swappable function of the DAQ system is very helpful for laboratory technicians to exchange modules according to project needs.

 

Precise time synchronization and simplified routing

The iDAQ-900 series chassis provides fast bus access through the backplane to realize the connection between iDAQ modules. Among the timing signals are triggers and synchronization clocks, which control when the measurement cycle starts and stops, as well as the acquisition speed. Each DAQ module can be synchronized over the bus using the same clock and trigger events. This makes synchronization with Advantech iDAQ systems easy as they only need to be configured in the software, which also means no complex connections are required.

On top of the backplane bus, programmable function pins (PFPs) in the iDAQ-900 chassis provide a clock control interface. DAQ modules can be configured as input or output signal types, as well as single pulse or clock types. This provides great flexibility for field applications that need to be synchronized with external devices, or simply pulsed by other devices.

 

Rugged design to withstand harsh environments

Three factors make iDAQ systems rugged: resistance to vibration, resistance to EMC, and wide temperature range operation. The entire assembly is tested under 5Grms random vibration and 30G shock tests, which are designed to withstand the most extreme vibration scenarios. The iDAQ series adopts an aluminium alloy shell and has better EMC performance. Finally, the operating temperature range is -20 - 60°C, which will make it well suited to not only most factories but also many outdoor environments. iDAQ systems are designed to operate 24/7 in most factory and outdoor environments.

 

Some iDAQ module specifications

1. Sound vibration collection

iDAQ-801-AE 256kS/s/ch, 24-bit, 4-channel DSA iDAQ module

•Supports hot swapping

•4 channels simultaneous sampling 256kS/s

•24-bit resolution, IEPE powered

•Configurable anti-aliasing filter

•High gain, up to ±187.5mV input range

2. 8-channel 1M/ch high-speed synchronous acquisition

iDAQ-841-AE 8-channel 16-bit, 1MS/s/ch synchronous AI

•8 channels of simultaneous sampling up to 1 MS/s

• 16-bit resolution • Software-selectable low-pass filter

•Wide input range up to 40 vpp (±20 V range)

•Supports voltage and current measurements

3. High-speed digital DIO

iDAQ-731-AE 16-channel isolated DI, 16-channel isolated DO iDAQ module

•32-channel isolated DI/O (16-channel digital input, 16-channel digital output)

•Supports buffer acquisition/update rates up to 10kHz

•High drive capability, interrupt handling capability

•Digital output type can be switched between sink (NPN) type and source (NPN) type

•600VRMS isolation protection

Other iDAQ IO modules

 

  • IDAQ-731-AE: 16-channel isolated DI, 16-channel isolated DO iDAQ module module
  • IDAQ-763D-AE: 8-channel SSR output iDAQ module
  • IDAQ-801-AE: 256kS/s/ch, 24-bit, 4-channel DSA iDAQ module
  • IDAQ-817-AE: 200kS/s, 16-bit, 8-channel analog input iDAQ module
  • IDAQ-821-AE: 50kS/s, 16-bit, 4-channel analog output iDAQ module
  • IDAQ-841-AE: 8 channels 16 bits, 1MS/s/ch synchronous AI
  • IDAQ-934-AE: 4-slot USB3.0 iDAQ module chassis
  • IDAQ-964-AE: 4-slot stand-alone iDAQ module chassis compatible with AMAX-5580

 

 

Multiple interfaces, one SDK

The iDAQ-900 chassis offers different connectivity solutions depending on the modules installed. The iDAQ system relies on DAQNavi/SDK as a development package. It provides a Navigator utility to configure modules and chassis and test their functionality. This article provides sample code to help guide programmers on how to use the API suite. In addition, Advantech has released a Python SDK so that customers can quickly build and test their solutions and prove their reliability.

The iDAQ series comes with two types of chassis: the iDAQ-964 chassis with our AMAX series edge controllers and the iDAQ-934 chassis with USB connectivity. iDAQ system programming code is interchangeable between chassis. For example, a program completed based on iDAQ-934 can be moved directly to iDAQ-964 with only slight modifications to the device name. Due to its modular and robust design, simplified cabling and easy-to-use SDK, the Advantech IDAQ system will be ideal for future test and measurement scenarios that require DAQ testing challenges.

iDAQ-964 uses the AMAX-5580 edge controller for chassis expansion. The left side of AMAX-5580 supports 4 PCIE interface modules. iDAQ-964 occupies one module position and can also connect 3 AMAX expansion communication modules (serial port, CAN, camera, WIFI, 4G, 5G...).

 

Modular DAQ Selection Guide 

close

Request a quote

Unit target price with VAT, but without delivery.