EKI-1242IECMS Modbus RTU/TCP to EtherCAT Fieldbus Gateway, Wide Temperature

  • Model: DF-RP-625
  • Brand: Advantech
Price to be announced

Viewed 217 times

The EKI-1242IECMS industrial fieldbus gateway provides seamless communication between Fieldbus and Ethernet devices with its support for different protocol devices, thereby being capable of integrating new and existing Modbus RTU/TCP devices into EtherCAT networks. The EKI-1242IECMS is a simple and cost-effective way to bring the advantage of fast I/O data transfer between devices.

 

Features

  • Seamless integrate Modbus RTU/TCP and EtherCAT communication
  • Built-in real time diagnostic to increase highly efficiency of device management
  • Designed for protocol extensibility and adaption
  • Modbus TCP client mode supports 64 connections
  • Supports dual power input for power redundancy
  • Mounts on DIN-rail and Wall mount

 

Specifications

Download EKI-1242IECMS specifications [ENG, .pdf]

Mudel  EKI-1242IECMS-A
 Certification 
 EMC  CE, FCC Class A
 EMI  EN 55011/ EN 55022 Class A, EN 61000-6-4, FCC Part 15 Subpart B Class A
 EMS  EN 61000-4-2 (Level 4), EN 61000-4-3 (Level 3), EN 61000-4-4 (Level 4), EN 61000-4-5 (Level 4), EN 61000-4-6 (Level 3), EN 61000-4-8 (Level 4)
 Freefall  IEC 60068-2-32
 Shock  IEC 60068-2-27
 Vibration  IEC 60068-2-6
 Environment 
 Humidity (Operating Range)  10~90% RH non-condensing (refer to IEC 60068-2-3)
 Temperature (Max. Operating)  75°C (167°F)
 Temperature (Min. Operating)  -40°C (-40°F)
 Temperature (Operating Range)  -40 ~ 75°C (-40 ~ 167°F)
 Temperature (Storage Range)  -40 ~ 85°C (-40 ~ 185°F)
 Ethernet Communication 
 Ethernet Standard  IEEE 802.3 , 802.3ab , 802.3u
 RJ-45 Port Connector Type  RJ-45
 RJ-45 Port Number  4
 RJ-45 Transmission Speed  10/100 Mbps
 Protection 
 Port to Port Isolation  Built-in 1.5 KV magnetic isolation
 Reverse Polarity  Present
 Mechanism 
 Dimensions (W x H x D)   42 x 140 x 95 mm (1.65 x 5.51 x 3.74 in.)
 Enclosure (Metal)  Metal with solid mounting hardware
 Mounting (DIN-rail)  Yes
 Mounting (Wall)  Yes
 IP Rating  IP30
 Weight  0.497 kg
 Modbus Communication 
 Modbus RTU/TCP Functions Support  1,2,3,4,5,6,15,16,23
 Modbus RTU/TCP Mode  Client
 Power 
 Power Consumption  5.2W (system)
 Power Operating Current  0.22 @ 24V ;  0.11 @ 48V
 Power Input (DC)  12 ~ 48 VDC
 Serial Communication 
 Data Bits  7.8
 Flow Control  XON/XOFF, RTS/CTS, DTR/DSR
 Parity  None, Odd, Even, Space, Mark
 Serial Port Connector Type  DB9 male
 Serial Port Number  2
 RS-232  Yes
 RS-422  Yes
 RS-485  Yes
 Serial Signals  RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND
 Stop Bits  1, 2
 Serial Transmission Speed  50 ~ 921.6 kbps, any baud rate setting
 Software 
 EtherCAT Fmmu Channel  4
 EtherCAT Inout  512 bytes
 EtherCAT Max. Total I/O Data Size  (SDO&PDO objects)
 EtherCAT Outout  512 bytes
 Modbus RTU/TCP Functions Support  1, 2, 3, 4, 5, 6, 15, 16, 23
 Modbus RTU/TCP Max. No. of Connections  64 connections
 Modbus RTU/TCP Mode  Client
 Warranty 
 Warranty Period   5 years
  Protocol Support 
 Modbus TCP  Yes
 Modbus RTU  Yes
 EtherCAT  Yes
 Ethernet  Yes
 Modbus ASCII  Yes
close

Request a quote

Unit target price with VAT, but without delivery.