EKI-1242IECMS Modbus RTU/TCP to EtherCAT Fieldbus Gateway,
- Device model: DF-RP-625
- Brand: Advantech
Price to be announced
Viewed 753 times
The EKI-1242IECMS industrial fieldbus gateway provides seamless communication between Fieldbus and Ethernet devices with its support for different protocol devices, thereby being capable of integrating new and existing Modbus RTU/TCP devices into EtherCAT networks. The EKI-1242IECMS is a simple and cost-effective way to bring the advantage of fast I/O data transfer between devices.
Features
- Seamless integrate Modbus RTU/TCP and EtherCAT communication
- Built-in real time diagnostic to increase highly efficiency of device management
- Designed for protocol extensibility and adaption
- Modbus TCP client mode supports 64 connections
- Supports dual power input for power redundancy
- Mounts on DIN-rail and Wall mount
Specifications
Download EKI-1242IECMS specifications [ENG, .pdf]
| Mudel | EKI-1242IECMS-A |
| Certification | |
| EMC | CE, FCC Class A |
| EMI | EN 55011/ EN 55022 Class A, EN 61000-6-4, FCC Part 15 Subpart B Class A |
| EMS | EN 61000-4-2 (Level 4), EN 61000-4-3 (Level 3), EN 61000-4-4 (Level 4), EN 61000-4-5 (Level 4), EN 61000-4-6 (Level 3), EN 61000-4-8 (Level 4) |
| Freefall | IEC 60068-2-32 |
| Shock | IEC 60068-2-27 |
| Vibration | IEC 60068-2-6 |
| Environment | |
| Humidity (Operating Range) | 10~90% RH non-condensing (refer to IEC 60068-2-3) |
| Temperature (Max. Operating) | 75°C (167°F) |
| Temperature (Min. Operating) | -40°C (-40°F) |
| Temperature (Operating Range) | -40 ~ 75°C (-40 ~ 167°F) |
| Temperature (Storage Range) | -40 ~ 85°C (-40 ~ 185°F) |
| Ethernet Communication | |
| Ethernet Standard | IEEE 802.3 , 802.3ab , 802.3u |
| RJ-45 Port Connector Type | RJ-45 |
| RJ-45 Port Number | 4 |
| RJ-45 Transmission Speed | 10/100 Mbps |
| Protection | |
| Port to Port Isolation | Built-in 1.5 KV magnetic isolation |
| Reverse Polarity | Present |
| Mechanism | |
| Dimensions (W x H x D) | 42 x 140 x 95 mm (1.65 x 5.51 x 3.74 in.) |
| Enclosure (Metal) | Metal with solid mounting hardware |
| Mounting (DIN-rail) | Yes |
| Mounting (Wall) | Yes |
| IP Rating | IP30 |
| Weight | 0.497 kg |
| Modbus Communication | |
| Modbus RTU/TCP Functions Support | 1,2,3,4,5,6,15,16,23 |
| Modbus RTU/TCP Mode | Client |
| Power | |
| Power Consumption | 5.2W (system) |
| Power Operating Current | 0.22 @ 24V ; 0.11 @ 48V |
| Power Input (DC) | 12 ~ 48 VDC |
| Serial Communication | |
| Data Bits | 7.8 |
| Flow Control | XON/XOFF, RTS/CTS, DTR/DSR |
| Parity | None, Odd, Even, Space, Mark |
| Serial Port Connector Type | DB9 male |
| Serial Port Number | 2 |
| RS-232 | Yes |
| RS-422 | Yes |
| RS-485 | Yes |
| Serial Signals | RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND |
| Stop Bits | 1, 2 |
| Serial Transmission Speed | 50 ~ 921.6 kbps, any baud rate setting |
| Software | |
| EtherCAT Fmmu Channel | 4 |
| EtherCAT Inout | 512 bytes |
| EtherCAT Max. Total I/O Data Size | (SDO&PDO objects) |
| EtherCAT Outout | 512 bytes |
| Modbus RTU/TCP Functions Support | 1, 2, 3, 4, 5, 6, 15, 16, 23 |
| Modbus RTU/TCP Max. No. of Connections | 64 connections |
| Modbus RTU/TCP Mode | Client |
| Warranty | |
| Warranty Period | 5 years |
| Protocol Support | |
| Modbus TCP | Yes |
| Modbus RTU | Yes |
| EtherCAT | Yes |
| Ethernet | Yes |
| Modbus ASCII | Yes |